Load Switch

Results 41-42 of 42

Set Descending Direction
per page
Page
View List Grid
  1. Terminal Lugs,Dimension Reference D1,Used with 194R NJ200P3,194R NN200P3,194R NA400P3
    Availability:
    Forward delivery 5-7 weeks
  2. 80 A 194E Load switch
    Part No.: 194E-E80-1753
    80 A 194E Load switch
    UOM: EA

     

    Number of auxiliary contacts as normally open contact
    0
    Number of auxiliary contacts as normally closed contact
    0
    Conditioned rated short-circuit current Iq
    30 kA
    Rated permanent current Iu
    80 A
    Rated operation power at AC-23, 400 V
    37 kw
    Max. rated operation voltage Ue AC
    690 V
    Rated operation power at AC-3, 400 V
    30 kw
    Rated short-time withstand current lcw
    2500 kA
    Rated frequency
    60 Hz
    Switch size
    80 A
    Lost power per pole
    3.6 W
    Conventional free air thermal current (Ith)
    100 A per IEC
    Conventional enclosed thermal current (Ie)
    80 A per IEC
    Rated operational voltage (Ue)
    690V per IEC
    Rated isolation voltage (Ui)
    690V per IEC
    Continuous current
    UL/CSA (applications): 80 A
    Rated breaking capacity
    AC-23A (cosφ 0.45): 800A @ 400V
    Motor FLA rating
    UL/CSA application: 68A @ 240V, 60 Hz, 3 pole, 3 phase
    Hp motor rating
    UL/CSA application: 50Hp @ 600V, 60 Hz, 3 pole, 3 phase
    Fuse rating of circuit (type g, G), max
    Short circuit current (co-ordination type 2): 80A @ 400/415V
    Rated current (Ie)
    DC-21A (for resistive loads): 80A @ 96V, 2 pole in series, T ≤1 ms, Ue max = 660V
    Rated power (Pe)
    AC-3: 30 kW @ 690V
    Number of switches
    1
    Motor drive integrated
    False
    Voltage release optional
    False
    Type of electrical connection of main circuit
    Screw connection
    Switching rate
    120 ops/h
    Rated impulse voltage (Uimp)
    8 kV per UL, CSA
    Test voltage (Ui)
    2.5kV @ 1min
     
    Version as emergency stop installation
    False
    Degree of protection (NEMA)
    Other
    Tightening torque
    5.6 Nm (50 in-lb)
    Switch configuration
    OFF-ON 90°
    Rigid wire gauge
    4...50 mm2 (10...1 AWG)
    Fine strands wire gauge
    4...35 mm2 (10...1 AWG)
    Knockouts
    PG-type cable gland entry
    Wire gauge, max
    Terminal size per IEC 947-1: A9
    Protection class according to IEC 529
    Switch bodies: IP20 @ motor rating 60 Hz
    Actuator type
    Select actuator separately
    Version as reversing switch
    False
    Version as main switch
    True
    Version as maintenance-/service switch
    True
    Ambient enclosed temperature
    -20 °C
    Ambient storage temperature
    -40 °C
    Ambient operation temperature
    -25 °C
    More
    Availability:
    Forward delivery 5-7 weeks

Results 41-42 of 42

Set Descending Direction
per page
Page
View List Grid