RCBO 20A C 10mA 1+N pole 10kA eRBM-20/1/C/001-ME
Article No.:
153235
Part No.:
eRBM-20/1/C/001-ME
Brand:

Type |
RCBO
|
Application |
Switchgear for residential and commercial applications
|
Voltage rating |
240 V - 240 V
|
Surge current capacity |
0.25 kA
|
Voltage type |
AC
|
Width in number of modular spacings |
1
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Operating ambient temperature - max |
40 °C
|
Operating ambient temperature - min |
-25 °C
|
Product application |
Switchgear for residential and commercial applications
|
Rated current |
20 A
|
Rated operational current for specified heat dissipation (In) |
20 A
|
Static heat dissipation, non-current-dependent |
0 W
|
Built-in depth |
69.5 mm
|
Current limiting class |
3
|
Rated short-circuit breaking capacity (EN 60947-2) |
0 kA
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-25 °C
|
Fault current rating |
0.1 A
|
Heat dissipation capacity |
0 W
|
Heat dissipation per pole, current-dependent |
0 W
|
Number of poles (protected) |
1
|
Number of poles (total) |
1
|
Rated operational voltage (Ue) - max |
240 V
|
Rated short-circuit breaking capacity (IEC 60947-2) |
0 kA
|
Basic function |
Combined RCD/MCB devices
|
Equipment heat dissipation, current-dependent |
6.3 W
|
Rated impulse withstand voltage (Uimp) |
4 kV
|
Degree of protection |
IP20
|
Overvoltage category |
III
|
Pollution degree |
2
|
Leakage current type |
AC
|
Release characteristic |
C
|
Frequency rating |
50/60 Hz
|
Rated insulation voltage (Ui) |
500 V
|
Connectable conductor cross section (solid-core) - min |
1 mm²
|
Connectable conductor cross section (solid-core) - max |
25 mm²
|
Connectable conductor cross section (multi-wired) - min |
1 mm²
|
Connectable conductor cross section (multi-wired) - max |
25 mm²
|
Rated short-circuit breaking capacity (EN 61009) |
10 kA
|
Rated short-circuit breaking capacity (EN 61009-1) |
10 kA
|
Number of poles |
Single-pole
|
Disconnection characteristic |
Undelayed
|
Power loss |
6.3 W
|