Search results for: 'brands rittal others general padlock for lzm1 nzm1'
- Did you mean
- brandles rittal others general padlock for lamp nzm
- brands rittal others general padlock 2 for lzm1 nzm1
-
Part No.: 700-HC24Z01-3GENERAL PURPOSE SQUARE W/ BLADE TERMINALUOM: EAGENERAL PURPOSE SQUARE W/ BLADE TERMINAL
Availability:Forward delivery 5-7 weeks -
Part No.: 700-HC22Z12-3GENERAL PURPOSE RELAY 10A SILVER PLATEDUOM: EAGENERAL PURPOSE RELAY 10A SILVER PLATED
Availability: In stock -
Part No.: 1756-M08SEGControlLogix Generic Motion ModuleUOM: EAModule,Generic Motion,8 Axis,Servo - SERCOS
Availability:Forward delivery 5-7 weeks -
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-IFD1-D650PowerFlex 700L Rittal Door KitUOM: EADoor Kit,Input Filter,400-480V,600 mm,Size 3A Frame,Rittal
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-IFD1-F705PowerFlex 700L Rittal Door KitUOM: EADoor Kit,Input Filter,600-690V,600 mm,Size 3B Frame,Rittal
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-IFD1-F380PowerFlex 700L Rittal Door KitUOM: EADoor Kit,Input Filter,600-690V,600 mm,Size 3A Frame,Rittal
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-IFD1-D1250PowerFlex 700L Rittal Door KitUOM: EADoor Kit,Input Filter,400-480V,600 mm,Size 3B Frame,Rittal
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-FLTR1-FB3PowerFlex 700L Rittal Door KitUOM: EADoor Kit,Air Filter,Power Module Cabinet,Size 3A-3B Frame,Rittal
Availability:Forward delivery 5-7 weeks -
Part No.: NZM1-XTVDDoor coupling rotary handle, lockable, size 1 NZM1-XTVDUOM: EADoor coupling rotary handle, lockable, size 1
Availability: In stock -
Part No.: 1756-M08SEGKControlLogix 8 Axis GENERIC Servo ModuleUOM: EAServo Motion Control Module,ControlLogix,8 Axis,Generic, Conformal coated
Availability:Forward delivery 5-7 weeks -
Part No.: NZM1-XTVDVRDoor coupling rotary handle, red-yellow for emergency switching off, size 1. NZM1-XTVDVRUOM: EA
Availability:Forward delivery 5-7 weeks -
Availability:Forward delivery 5-7 weeks -
Part No.: 1443-ACC-GP-TGeneral Purpose AccelerometerUOM: EAGeneral Purpose Accel, Top Exit, 100mV/g
Availability:Forward delivery 5-7 weeks -
Part No.: NZM1-XA208-250AC/DCShunt release, 208-240VAC/DC. NZM1-XA208-250AC/DCUOM: EAShunt release, 208-240VAC/DC
Availability:Forward delivery 5-7 weeks -
Part No.: NZM1-XAHIV208-250AC/DCShunt release, 208-240VAC/DC, +1early N/O - NZM1-XAHIV208-250AC/DCUOM: EAUsed with NZM1(-4), N(S)1(-4)Type - Accessory
- Shunt release
Special features - Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
Voltage rating 0.7 - 1.1 x Us10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.2 Corrosion resistance Meets the product standard's requirements.10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects Meets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.10.2.7 Inscriptions Meets the product standard's requirements.10.3 Degree of protection of assemblies Does not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distances Meets the product standard's requirements.10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connections Is the panel builder's responsibility.10.8 Connections for external conductors Is the panel builder's responsibility.10.9.2 Power-frequency electric strength Is the panel builder's responsibility.10.9.3 Impulse withstand voltage Is the panel builder's responsibility.10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.Electric connection type Screw connectionFrame NZM1Frequency rating 50 Hz / 60 Hz / 200 Hz / 400 Hz, DC (shunt release)Minimum command time - max 15 msMinimum command time - min 10 msNumber of contacts (normally open contacts) 0Reaction time 20 msPick-up power consumption (shunt release) 2.5 VA/WRated control supply voltage 208 - 250 V AC/DCRated control supply voltage (Us) at AC, 50 Hz - max 250 VRated control supply voltage (Us) at AC, 50 Hz - min 208 VRated control supply voltage (Us) at AC, 60 Hz - max 250 VRated control supply voltage (Us) at AC, 60 Hz - min 208 VSuitable for Off-load switchConnection type With terminal block on the left-hand switch sideVoltage type AC/DCTerminal capacity (solid/flexible conductor) 0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt releaseRated control supply voltage (Us) at DC - max 250 VRated control supply voltage (Us) at DC - min 208 VVoltage rating at AC (x Us) - max 1.1Voltage rating at AC (x Us) - min .7Number of contacts (normally closed contacts) 0Number of contacts (change-over contacts) 0Undelayed short-circuit release - min 0 AUndelayed short-circuit release - max 0 ATime on duty - max ∞Rated control voltage (relay contacts) 208 V DC
250 V DC
250 V AC
208 V ACMore
Availability:Forward delivery 5-7 weeks -
Availability:Forward delivery 5-7 weeks -
Part No.: DEKRA-RPTDEKRA Test for IP 55 RITTAL Enclosure H 2000 x W 800 x D 1200 as per enclosed GENERAL ARRANGMENT provided by Al Ghandi Switchgear Industry including DEKRA Test ReportUOM: EA
Availability:Forward delivery 5-7 weeks -
Part No.: 2493000Lock cover for padlocks or multiple locks - 2493000UOM: EAFor retrospective mounting on all sheet steel compact enclosures, sheet steel, with cam lock.
Material: Die-cast zincSurface finish: Nickel-platedTo fit enclosure type: AX with camKX E-BoxAE with camCX one-piece consoleCX desk unitMore
Availability:Forward delivery 5-7 weeks -
Availability: In stock













