Search results for: 'brands eaton push buttons sensors m22 command control undervoltage release 208 240vac'
-
Part No.: NZM1-XU208-240ACUndervoltage release, 208-240VACUOM: EAUndervoltage release, 208-240VAC
Availability: In stock -
Part No.: NZM4-XU208-240ACUndervoltage release, 208-240VACUOM: EAUndervoltage release, 208-240VAC
Availability: In stock -
Part No.: NZM2/3-XU208-240ACUndervoltage release, 208-240VACUOM: EAUndervoltage release, 208-240VAC
Availability: In stock -
Availability:Forward delivery 5-7 weeks -
Part No.: IZMX-UVR230AD-1UNDERVOLTAGE RELEASE 220-240 VAC/DC. IZMX-UVR230AD-1UOM: EAUndervoltage release 220-240 VAC/DC
Availability: In stock -
Availability: In stock -
Part No.: BZM1-3-XA230-240VACBZM1-3-XA230-240VAC - Shunt release (for power circuit breaker), 230-240VACUOM: EAShunt release (for power circuit breaker), 230-240VAC
Availability:Forward delivery 5-7 weeks -
Part No.: NZM1-XA208-250AC/DCShunt release, 208-240VAC/DC. NZM1-XA208-250AC/DCUOM: EAShunt release, 208-240VAC/DC
Availability:Forward delivery 5-7 weeks -
Part No.: NZM2/3-XA208-250AC/DCSHUNT RELEASE, 208-240VAC/DC. NZM2/3-XA208-250AC/DCUOM: EAShunt release, 208-240VAC/DC
Availability: In stock -
Part No.: NZM1-XAHIV208-250AC/DCShunt release, 208-240VAC/DC, +1early N/O - NZM1-XAHIV208-250AC/DCUOM: EAUsed with NZM1(-4), N(S)1(-4)Type - Accessory
- Shunt release
Special features - Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
Voltage rating 0.7 - 1.1 x Us10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.2 Corrosion resistance Meets the product standard's requirements.10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects Meets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.10.2.7 Inscriptions Meets the product standard's requirements.10.3 Degree of protection of assemblies Does not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distances Meets the product standard's requirements.10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connections Is the panel builder's responsibility.10.8 Connections for external conductors Is the panel builder's responsibility.10.9.2 Power-frequency electric strength Is the panel builder's responsibility.10.9.3 Impulse withstand voltage Is the panel builder's responsibility.10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.Electric connection type Screw connectionFrame NZM1Frequency rating 50 Hz / 60 Hz / 200 Hz / 400 Hz, DC (shunt release)Minimum command time - max 15 msMinimum command time - min 10 msNumber of contacts (normally open contacts) 0Reaction time 20 msPick-up power consumption (shunt release) 2.5 VA/WRated control supply voltage 208 - 250 V AC/DCRated control supply voltage (Us) at AC, 50 Hz - max 250 VRated control supply voltage (Us) at AC, 50 Hz - min 208 VRated control supply voltage (Us) at AC, 60 Hz - max 250 VRated control supply voltage (Us) at AC, 60 Hz - min 208 VSuitable for Off-load switchConnection type With terminal block on the left-hand switch sideVoltage type AC/DCTerminal capacity (solid/flexible conductor) 0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt releaseRated control supply voltage (Us) at DC - max 250 VRated control supply voltage (Us) at DC - min 208 VVoltage rating at AC (x Us) - max 1.1Voltage rating at AC (x Us) - min .7Number of contacts (normally closed contacts) 0Number of contacts (change-over contacts) 0Undelayed short-circuit release - min 0 AUndelayed short-circuit release - max 0 ATime on duty - max ∞Rated control voltage (relay contacts) 208 V DC
250 V DC
250 V AC
208 V ACMore
Availability:Forward delivery 5-7 weeks -
Part No.: NZM2/3-XUVHIVUndervoltage release, +2early N/O, for delay unit. NZM2/3-XUVHIVUOM: EAUndervoltage release, +2early N/O, for delay unit
Availability:Forward delivery 5-7 weeks -
Part No.: LV429407MN undervoltage release, ComPacT NSX, rated voltage 220/240 VAC 50/60 Hz, 208/277 VAC 60 Hz, screwless spring terminal connectionsUOM: EA
Availability: In stock -
Part No.: S3N 017-XN-X-XXDISCONNECT SWITCH INSERT, UNDERVOLTAGE RELEASE 400V/50HZ BASE MOUNTINGUOM: EA
Availability:Forward delivery 5-7 weeks -
Availability:Forward delivery 5-7 weeks -
Part No.: 1769-CJCCompactLogix CJC Temperature SensorUOM: EACold Junction Compensation Sensor,CompactLogix,Used with Thermocouple Modules,Up to 2 used per 1769-IT6 module
Availability:Forward delivery 5-7 weeks -
Part No.: NZM4-XR208-240ACRemote operator, 208-240VAC, for size 4UOM: EARemote operator, 208-240VAC, for size 4
Availability:Forward delivery 5-7 weeks -
Availability: In stock -
Part No.: 800FP-LMP44PN5RX0122mm Momentary Push Button 800F PBUOM: EAPush Button, Mushroom Operator, 40mm, Red, Push-Pull/Twist-To-Release, Illuminated Red Integrated LED, Plastic Latch Mount, 120V AC, 1 N.C. Contact, Round Plastic (Type 4/4X/13, IP66), Pkg. Qty. of 1More
Availability:Forward delivery 5-7 weeks -
Part No.: NZM3-XR208-240ACNZM3-XR208-240AC - Remote operator, 208-240VAC, for size 3UOM: EARemote operator, 208-240VAC, for size 3
Availability: In stock -
Part No.: M22-PVT45PEaton Moeller® series M22 Emergency stop/emergency switching off pushbuttonUOM: EAEmergency stop/emergency switching off pushbutton, RMQ-Titan, Palm-tree shape, 45 mm, Non-illuminated, Turn-to-release function, Red, yellow, RAL 3000More
Availability: In stock -
Part No.: 1769-OA16KCompactLogix 16 Pt 240VAC D/O ModuleUOM: EA16 channel 240VAC AC Output with conformal coating
Availability:Forward delivery 5-7 weeks -
Part No.: SK-R1-INVIFB1-F8PowerFlex 750 Current Sensor KitUOM: EACurrent Sensor Kit,Inverter,Size 8 Frame
Availability:Forward delivery 5-7 weeks -
Part No.: SK-L1-TH1-FB3PowerFlex 700L Temperature Sensor KitUOM: EAPowerFlex 700L Kit,Temperature Sensor Harness,Frame 3B
Availability:Forward delivery 5-7 weeks -
Part No.: IZMX-SR230AD-1IZMX-SR230AD-1 - Spring release 220-240 VAC/DCUOM: EAClosing release 220-240 VAC/DC
Availability:Forward delivery 5-7 weeks -
Part No.: 800FP-G4PX04800F PUSH BUTTON, PLASTIC, GUARDEDUOM: EA800F PUSH BUTTON, PLASTIC, GUARDED
Availability:Forward delivery 5-7 weeks -
Availability:Forward delivery 5-7 weeks -
Part No.: 8LM2TB6644RED MUSHROOM-HEAD PUSH BUTTON ACTUATOR SUOM: EAPUSH-BUTTONS AND SELECTOR SWITCHES
Availability:Forward delivery 5-7 weeks



