AMPERAGE RATING 800 A
TRIP TYPE T186
CIRCUIT BREAKER TYPE HMDL
CIRCUIT BREAKER FRAMETYPE Complete breaker
SERIES Series C
FRAME MDL
INTERRUPT RATING 100 kAIC at 240 Vac & 65 kAIC at 480 Vac
NUMBER OF POLES Three-pole
Product specifications
AMPERAGE RATING 2000 A
TRIP TYPE T172
CIRCUIT BREAKER TYPE RG
CIRCUIT BREAKER FRAMETYPE Complete breaker
RATING 80% rated
SERIES 80% rated
TERMINALS Line and load
INTERRUPT RATING 125 kAIC at 240 Vac & 65 kAIC at 480 Vac
NUMBER OF POLES Three-pole
TYPE Complete breaker
| Amperage Rating |
600 A
|
| Voltage rating |
600 Vac, 250 Vdc
|
| Trip Type |
T167
|
| Circuit breaker type |
CLDC
|
| Circuit breaker frame type |
Complete breaker
|
| Rating |
100% rated
|
| Series |
Series C
|
| Terminals |
Without terminals
|
| Frame |
L
|
| Frequency rating |
50 to 60 Hz
|
| Class |
Naval
|
| Calibration |
50°C
|
| Rated permanent current |
Adjustable
|
| Rating plug |
A6LES600T1 interchangeable
|
| Interrupt rating |
100 kAIC at 480 Vac
200 kAIC at 240 Vac |
| Number of poles |
Three-pole
|
| Trip rating |
600 A
|
| Type |
Current limiting
|
| Warranty |
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
|
| Certifications |
UL 489 Supplement S
|
Product specifications
LAMP TYPE LED
LETTER COLOR Red
LETTERING DIRECTION Horizontal
VOLTAGE RATING 120-277 Vac, 110-250 Vdc
FREQUENCY RATING 50/60 Hz
MOUNTING Wall
ENTRY SIZE 3/4"
MATERIAL Aluminum alloy
SPECIAL FEATURES With nickel cadmium battery, self-test
| Amperage Rating |
0.5A - 63A
|
| Number of poles |
Two-pole
|
| Type |
Module size 2
|
| Voltage rating |
440 Vac
|
| Tripping characteristic |
Characteristic C
|
| Trip rating |
6A
|
| Material |
Polyamide
|
| Mounting style |
Snap-on rail
|
| Special features |
Max. back-up fuse gL 40A, 10 kA
|
| Area classification |
Hazardous/Classified Locations
|
| Standards type |
IECEx/ATEX IEC
|
| Amperage Rating | 0.5A - 63A |
| Number of poles | Two-pole |
| Type | Module size 2 |
| Voltage rating | 440 Vac |
| Tripping characteristic | Characteristic C |
| Trip rating | 4A |
| Material | Polyamide |
| Mounting style | Snap-on rail |
| Special features | Max. back-up fuse gL 20A, 10 kA |
|
Area classification
|
Hazardous/Classified Locations
|
|
Standards type
|
IECEx/ATEX IEC
|
| Amperage Rating | 0.5A - 63A |
| Number of poles | Two-pole |
| Type | Module size 2 |
| Voltage rating | 440 Vac |
| Tripping characteristic | Characteristic C |
| Trip rating | 16A |
| Material | Polyamide |
| Mounting style | Snap-on rail |
| Special features | Max. back-up fuse gL 100A, 10 kA |
Certifications and compliances
| Area classification | Hazardous/Classified Locations |
| Standards type | IECEx/ATEX IEC |
| Amperage Rating |
0.5A - 63A
|
| Number of poles |
Two-pole
|
| Type |
Module size 2
|
| Voltage rating |
440 Vac
|
| Tripping characteristic |
Characteristic C
|
| Trip rating |
10A
|
| Material |
Polyamide
|
| Mounting style |
Snap-on rail
|
| Special features |
Max. back-up fuse gL 100A, 10 kA
|
| Area classification |
Hazardous/Classified Locations
|
| Standards type |
IECEx/ATEX IEC
|
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 5" cover opening diameter, Feraloy iron alloy, C shape, 1-1/2"
| Product Name |
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
|
| Catalog Number |
GUAC59
|
| Area classification |
Hazardous/Classified Locations
|
| Standards type |
NEC/CEC
|
| NEC hazardous rating |
Class I, Division 1 Class I, Division 2 Class II, Division 1 ,Class II, Division 2
Class III |
| NEMA Rating |
3 ,4 ,7, 9
|
| Shape |
C
|
| Trade size |
1-1/2"
|
| Cover opening diameter |
5"
|
| Material |
Feraloy iron alloy
|
| Shape |
X
|
| Trade size |
1-1/2"
|
| Cover opening diameter |
5"
|
| Material |
Feraloy iron alloy
|
| Area classification |
Hazardous/Classified Locations
|
| Standards type |
NEC/CEC
|
| NEC hazardous rating |
Class I, Division 1, Class I, Division 2
Class II, Division 1 , Class II, Division 2 Class III
|
| NEMA Rating |
3, 4, 7, 9
|
| Shape |
X
|
| Trade size |
1-1/2"
|
| Cover opening diameter |
5"
|
| Material |
Feraloy iron alloy
|
| Area classification |
Hazardous/Classified Locations
|
| Standards type |
NEC/CEC
|
| NEC hazardous rating |
Class I, Division 1, Class I, Division 2
Class II, Division 1 , Class II, Division 2 Class III
|
| NEMA Rating |
3, 4, 7, 9
|
Eaton Power Defense molded case circuit breaker, Globally Rated, Frame 2, Two Pole, 30A, 25kA/480V, T-M (Fxd-Fxd) TU, Standard Line and Load (PDG2X2T100)
| Amperage Rating |
30 A
|
| Voltage rating |
600 Vac
|
| Trip Type |
T298
|
| Circuit breaker type |
PD2 Global
|
| Circuit breaker frame type |
Complete breaker
|
| Terminals |
Standard Line and Load
|
| Frame |
2
|
| Class |
Class A
|
| Interrupt rating |
25 kAIC at 480 Vac
|
| Rated operation voltage (Ue) at AC - max |
600
|
| Switch off technique |
Thermomagnetic
|
| Voltage rating - max |
600 V
|
| Interrupt rating range |
25 kAIC @480V (UL)
10 kAIC Icu @125 Vdc 10 kAIC Icu @250 Vdc 18 kAIC Icu/ 15/13 kAIC Ics/ 37.8 kAIC Icm @525V South Africa (IEC) 25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @440V (IEC) 25 kAIC Icu/ 25 kAIC Ics/ 52.5 kAIC Icm @380-415V (IEC) 20 kAIC Icu/ 20 kAIC Ics/ 42 kAIC Icm @480V Brazil (IEC) 14 kAIC @600V (UL/CSA) 35 kAIC @240V (UL) 35 kAIC Icu/ 35 kAIC Ics/ 73.5 kAIC Icm @240V (IEC) |
| Number of poles |
Two-pole
|
| Compliances |
RoHS Compliant
|
| Certifications |
CCC Marked
CSA IEC 60947-2 UL 489 |
| Special features | Copper connectors, mounting brackets, covers, hardware and instructions |
| Type | Panelboard Connector Kit |
| Special features |
Copper connectors, mounting brackets, covers, hardware and instructions
|
| Type |
Panelboard Connector Kit
|
| Special features |
Copper connectors, mounting brackets, covers, hardware and instructions
|
| Type |
Panelboard Connector Kit
|
| Global Catalog |
KPRL3X23
|
| Catalog Notes |
Breakers are not included.
|
| Certifications |
UL Listed
|
| Product Name |
Eaton Power Defense molded case circuit breaker
|
| Catalog Number |
PDG23M0200TFFL
|
| Warranty |
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
|
| Compliances |
RoHS Compliant
|
| Certifications |
IEC 60947-2 ,UL 489 ,CCC Marked, CSA
|
| Amperage Rating |
200 A
|
| Circuit breaker frame type |
Complete breaker
|
| Frame |
2
|
| Number of poles |
Three-pole
|
| Circuit breaker type |
PD2 Global
|
| Class |
Class A
|
| Trip Type |
T298
|
| Voltage rating |
600 Vac
|
| Terminals |
Standard Terminals Load Only
|
| Interrupt rating |
65 kAIC at 480 Vac
|
| Interrupt rating range |
65 kAIC @480V (UL)
100 kAIC @240V (UL) 30/25 kAIC Icu/ 15/13 kAIC Ics @525V South Africa (IEC) 10 kAIC Icu/ 5 kAIC Ics/ 21 kAIC Icm @690V (IEC) 70 kAIC Icu/ 53 kAIC Ics/ 154 kAIC Icm @380-415V (IEC) 22 kAIC Icu @250 Vdc 50 kAIC Icu/ 30 kAIC Ics/ 105 kAIC Icm @480V Brazil (IEC) 100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC) 35 kAIC @600V (UL/CSA) 50 kAIC Icu/ 40 kAIC Ics/ 105 kAIC Icm @440V (IEC) 22 kAIC Icu @125 Vdc |